WhatsApp/Wechat:+86-15254140530

COMPANY PRODUCT

DWC Impact Specimen Low Temperature Cooling Chamber

NO: DWC-40, DWC-60, DWC-80, DWC-100
  • JB-300B 300J Semi-automatic Charpy Pendulum Metal Impact Tester
  • CST-50 Impact Specimen Profile Projector
  • UV-1S Manual Control Impact Specimen Notch Broaching Machine
  • UV-2Y Impact Specimen Notch Hydraulic Broaching Machine

Share With:

We"re here to help:
Easy ways to get the answers you need.
Send E-mail WhatsAPP/Wechat
+86-15254140530
1. Simple Introduction
Low temperature impact test tank, Is an impact test and supporting the provision of low-temperature environment for its sample a special test equipment, For cooling the sample at a low temperature impact test, Without ice, Cooling speed, High precision temperature control is a new cooling methods - cascade cryogenic refrigeration compressor device (or liquid nitrogen cooling).

The standard used:JB-5376-91《Cryostat tank technology》,GB/T229-2007《Metal Charpy pendulum impact test method》,GB/T 8363-2007《Ferritic steel drop weight tear tests》 in the low-temperature test equipment and temperature requirements (± 1 ℃),As well as the temperature index American standard, European standard of ASTM E23-02a, EN10045, ISO148, ISO83 and other relevant standards as stipulated.
Belongs Material: Metal Material
Industry: Widely used in low-temperature physics and chemistry test petrochemical, metallurgy, boiler and pressure vessel steel, steel, metal, casting, pumps, valves, fasteners, travel, machinery manufacturing, aerospace and scientific research and other industry sectors.
Test type: low temperature physics and chemistry test

 Its biggest advantage is simple, safe, fast, reliable, automatic thermostat, cooling only power without ice, cooling speed, large volume, high precision temperature control.
Technical Specifications DWC-30 DWC-40 DWC-60 DWC-80 DWC-100
Temperature range (adjustable settings) +30~-30℃ +30~-40℃ +30~-60℃ +30~-80℃ +30~-100℃
   Drop
 Warm
 Speed
 Degree
+30~0℃ Approximately 1.8℃/min Approximately 1.8℃/min Approximately 1.5℃/min Approximately 1.5℃/min Approximately 1.5℃/min
0~-20℃ Approximately 0.8℃/min Approximately 1.0℃/min Approximately 1.2℃/min Approximately 1.2℃/min Approximately 1.2℃/min
-20~-40℃ 约0.5℃/min 约0.8℃/min 约1.0℃/min 约1.0℃/min Approximately 1.2℃/min
-40~-60℃     Approximately 0.7℃/min Approximately 0.8℃/min Approximately 1.0℃/min
-60~-80℃       Approximately 0.5℃/min Approximately 0.8℃/min
-80~-100℃         Approximately 0.5℃/min
Temperature accuracy ﹤±0.5℃
Cold chamber volume 150×150×240mm(L × W × H)
Number of samples can be loaded More than 60, up to 120 standard sample
Cooling medium Ethanol or other antifreeze
Dimensions (mm) 905×510×870 905×510×870 905×510×870 905×510×870 905×510×870
Power supply 220~240V   1.0KW 220~240V   1.0KW 220~240V  1.5KW 220~240V  2.0KW 220~240V  2.5KW
Weight about50Kg about60Kg about100Kg about120Kg about150Kg

 

 


Contact Us now

Phone/WhatsApp*
Your Email*
Company Name*
Your Name*
Country