FT-9000 OES Optical Emission Spectrometers
NO:Middle Low Carbon Steel / Alloy / Brass SpectrometerWe"re here to help:
Easy ways to get the answers you need. Send E-mail WhatsAPP/Wechat
+86-15254140530
Easy ways to get the answers you need. Send E-mail WhatsAPP/Wechat
+86-15254140530
1. Application and Descriptions:
FT-9000 is Full Range of Solutions for the Entire Metals Industry. It use full-digital technology to replace bulky photomultiplier tube (PMT) simulation technology and keep pace with international spectrometer technology. The adoption of vacuum optical chamber design, full-digital excitation light source, advanced CCD detectors, and high-speed data readout system equips the device with high properties, ultra-low limit of detection (LOD), long-term stability and repeatability. The analytical precision can meet the requirements of laboratory standard, the analytical date is stable and reliable. Widely used in Metallurgy, casting, machinery processing and other industries incoming and outgoing product quality control.
The instrument is calibrated with limited standard samples which Jinan Focus Test Instrument Co.,Ltd have for general purpose. For special alloy and special elements, the instrument must be calibrated by customer themselves. Or if customer is willing to provide sample collaboration for program development, the customer must provide accurate sample element content tables and ensure sample uniformity, but such curves are not used as acceptance indicators of the instrument.
If the customer has type sample demand, the type sample number can be provided, and the customer can purchase the type sample by himself; if the salesman buys the type sample on behalf of the salesman, the type sample will be shipped separately by Jinan FocusTest.
Main Parameters:
3. Core Components
FT-9000 is Full Range of Solutions for the Entire Metals Industry. It use full-digital technology to replace bulky photomultiplier tube (PMT) simulation technology and keep pace with international spectrometer technology. The adoption of vacuum optical chamber design, full-digital excitation light source, advanced CCD detectors, and high-speed data readout system equips the device with high properties, ultra-low limit of detection (LOD), long-term stability and repeatability. The analytical precision can meet the requirements of laboratory standard, the analytical date is stable and reliable. Widely used in Metallurgy, casting, machinery processing and other industries incoming and outgoing product quality control.
The instrument is calibrated with limited standard samples which Jinan Focus Test Instrument Co.,Ltd have for general purpose. For special alloy and special elements, the instrument must be calibrated by customer themselves. Or if customer is willing to provide sample collaboration for program development, the customer must provide accurate sample element content tables and ensure sample uniformity, but such curves are not used as acceptance indicators of the instrument.
If the customer has type sample demand, the type sample number can be provided, and the customer can purchase the type sample by himself; if the salesman buys the type sample on behalf of the salesman, the type sample will be shipped separately by Jinan FocusTest.
Main Parameters:
Item | Index | |
Optical System |
Focal Length | 400mm |
Wavelength range | 130nm-800nm | |
Detector | High resolution CCD Multi detectors | |
Degree of vacuum | Auto control within 6-20 pa | |
Pixel resolution | 30pm | |
Grating line | 2400m1/mm | |
First order spectral line dispersion rare | 1.2nm/mm | |
Average resolution ratio | 10pm/pixel | |
Full spectrum | ||
Light room temperature is controlled automatically | ||
Spark Source |
Type | Digital arc and spark source |
Spark frequency | 100-1000HZ | |
Discharge current | 1-400A | |
Ignition voltage | >15000V | |
Excitation light |
Optimization of discharge parameters design | |
High energy precombustion technology HEPS | ||
Processor |
High-speed data synchronization acquisition and processing | |
Spark Stand |
Electrode | Tungsten electrode technology |
Make up | Thermal deformation self-compensation design | |
Argon flushed with minimal consumption of Argon | ||
Spray discharge electrode technology | ||
Adjustable electrode technology | ||
Others |
Measurable elements | Fe、Al、Cu、Ni、Ti、Co、Zn、Sn、Mg、Pb etc |
Dimension | 800mm(L)*700mm*470mm(H) | |
weight | About 100kg | |
Storage temperature | 0℃-45℃ | |
Operating temperature | 10℃-35℃, 23±2℃ is recommended | |
Power | AC220V/50Hz(Customized) | |
Power consumption | Excitation:700W/Stand by:100W | |
Argon quality | 99.999%, Argon pressure>4Mpa | |
Argon consumption | 5L/min during spark mode | |
Interface | Ethernet data transmission based on DM9000A |
3. Core Components
No. | Product | Brand | Place of origin | Warranty period |
1 | Grating | Zeiss | Germany | 15 years |
2 | Linear array CCD | Sony | Japan | 8 years |
3 | Optical lens | Zeiss | Germany | 8 years |
4 | Optical fiber | Zeiss | Germany | 8 years |
5 | Slit | lenoxlaser | America | 10 years |
6 | Digital light source | FOCUSTEST | 3 years | |
7 | Regulating valve | Burkert | Germany | 10 years |
8 | Vacuum pump | China | 2 years | |
9 | Optical fiber | Agilent | America | 1 years |
10 | Filter | TDK | Japan | 2 years |
11 | Pressure sensor | SSI | Canada | 2 years |
12 | Magnetic valve | Burkert | Germany | 2 years |
13 | CMOS acquisition module | FOCUSTEST | 1 years | |
14 | Control module | FOCUSTEST | 1 years | |
15 | Integrated circuit board | FOCUSTEST | 1 years | |
16 | Excitation table module | FOCUSTEST | 2 years | |
17 | Spectral analysis software | FOCUSTEST | permanent | |
18 | Standard sample | China or Import |